Rodyti trumpą aprašą

dc.contributor.authorVaiškūnaitė, Rasa
dc.contributor.authorNavickaitė, Rūta
dc.date.accessioned2026-04-17T10:02:11Z
dc.date.available2026-04-17T10:02:11Z
dc.date.issued2011
dc.identifier.isbn9789955288268en_US
dc.identifier.issn2029-7106en_US
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/160288
dc.description.abstractThe efficiency of a biofilter filled with pine bark charge was evaluated under conditions of interchanging pH. Hydrogen ion concentration is significance for the growth of microorganisms, therefore biological metabolism is strongly dependent on pH. Many micro-organisms will only grow within a particular pH range. However, it is necessary to know, which pH values suits the best for microorganisms growing, that degrades VOC in most intensive way and increase biological air treating efficiency. As a rough rule of thumb, most biological microorganisms growth occurs near a neutral pH (pH=7) and wide deviations from this will impair the efficiency of the biofilter. Tests were performed with different pH regimes (4, 5, 6, 7, 8, 9 and 10) in pine bark charge. Depending on the maintained pH, spontaneous microorganism groups were cultivated in the biocharge. Moreover, the charge of pine bark generated a basic pH whereas a neutral pH is an optimum condition for bacterial growth. The results showed, that the obtained performance results revealed that the biofilter provided high removal efficiency E=98 % treating butanol which has a concentration С=5 mg/m³, butyl acetate (C=4 mg/m³, E=96 %), and xylene (E=81 %, C=7 mg/m³). Accordingly to the different pH value treating butanol environment conditions when pH=4, E=6.9 %; when pH=5 then E=49 %, when pH=6 then E=91.1 %, when pH=8 then E=91.1 %, when pH=9 then E=49 %, when pH=10 then E=8.6 %. Therefore, different environment condition (primary concentration, layer height of charge 0.15 – 0.75 m, air flow rate 0.02–0.1 m/s) were tested to ascertain dependence on pH value and biological air treatment efficiency.en_US
dc.format.extent9 p.en_US
dc.format.mediumTekstas / Texten_US
dc.language.isoenen_US
dc.relation.urihttps://etalpykla.vilniustech.lt/handle/123456789/160185en_US
dc.source.urihttp://enviro2011.vgtu.lt/Abstracts/1/072.htmlen_US
dc.subjectbiofilteren_US
dc.subjectbiofiltrationen_US
dc.subjectvolatile organic compoundsen_US
dc.subjectspontaneous microorganismsen_US
dc.subjectbiocharge pHen_US
dc.titleEvaluation of the performance with biofilter effectiveness treating volatile organic compounds under different pH valueen_US
dc.typeKonferencijos publikacija / Conference paperen_US
dcterms.accessRightsLaisvai prieinamas / Openly availableen_US
dcterms.accrualMethodRankinis pateikimas / Manual submissionen_US
dcterms.alternativeEnvironmental Protectionen_US
dcterms.issued2011-05-20
dcterms.references23en_US
dc.description.versionTaip / Yesen_US
dc.contributor.institutionVilniaus Gedimino technikos universitetasen_US
dc.contributor.institutionVilnius Gediminas Technical Universityen_US
dc.contributor.facultyAplinkos inžinerijos fakultetas / Faculty of Environmental Engineeringen_US
dc.contributor.departmentAplinkos apsaugos ir vandens inžinerijos katedra / Department of Environmental Protection and Water Engineeringen_US
dcterms.sourcetitle8th International Conference “Environmental Engineering” (ICEE-2011)en_US
dc.identifier.eisbn9789955288275en_US
dc.identifier.eissn2029-7092en_US
dc.publisher.nameVilnius Gediminas Technical Universityen_US
dc.publisher.nameVilniaus Gedimino technikos universitetasen_US
dc.publisher.countryLithuaniaen_US
dc.publisher.countryLietuvaen_US
dc.publisher.cityVilniusen_US


Šio įrašo failai

Thumbnail

Šis įrašas yra šioje (-se) kolekcijoje (-ose)

Rodyti trumpą aprašą