Show simple item record

dc.contributor.authorAlbrektienė, Ramunė
dc.contributor.authorRimeika, Mindaugas
dc.contributor.authorLubytė, Ernesta
dc.date.accessioned2026-04-20T12:59:37Z
dc.date.available2026-04-20T12:59:37Z
dc.date.issued2011
dc.identifier.isbn9789955288282en_US
dc.identifier.issn2029-7106en_US
dc.identifier.urihttps://etalpykla.vilniustech.lt/handle/123456789/160305
dc.description.abstractThe main problem of drinking water in Lithuania is high iron concentrations. Traditional methods can be used to remove iron from water; however, if drinking water contains organic matters, these matters have a negative effect on the process of iron removal from it. Because of the organic matters on the grain surface of screen filler, a membrane, which reduces the possibility of iron removal, is formed. There are also humus-iron complexes of organic origin that hinder iron removal. The article discusses the possibilities of removal of iron-organic complexes using the coagulant poly-aluminium chloride (PAC). During the investigation, different dose of coagulant was added into each drinking water sample; the process of coagulation was carried out, and then water was filtered. Measurements of concentration of total iron, permanganate index, pH and residual aluminium were conducted after the process of coagulation. The aim of this study was to establish the conditions under which the process of coagulation is most effective, iron organic complexes are removed from drinking water and its quality is maintained. The study established that water pH has the greatest impact on the removal of iron-organic complexes from drinking water. Iron-organic complexes are best eliminated from drinking water when its pH is from 6.8 to 6.5.en_US
dc.format.extent4 p.en_US
dc.format.mediumTekstas / Texten_US
dc.language.isoenen_US
dc.relation.urihttps://etalpykla.vilniustech.lt/handle/123456789/160185en_US
dc.source.urihttp://enviro2011.vgtu.lt/Abstracts/2/089.htmlen_US
dc.subjectdrinking wateren_US
dc.subjectiron-organic complexesen_US
dc.subjectpermanganate indexen_US
dc.subjectcoagulationen_US
dc.subjectpoly-aluminium chloride (PAC)en_US
dc.titleThe removal of iron-organic complexes from drinking water using coagulation processen_US
dc.typeKonferencijos publikacija / Conference paperen_US
dcterms.accessRightsLaisvai prieinamas / Openly availableen_US
dcterms.accrualMethodRankinis pateikimas / Manual submissionen_US
dcterms.alternativeWater Engineeringen_US
dcterms.issued2011-05-20
dcterms.references20en_US
dc.description.versionTaip / Yesen_US
dc.contributor.institutionVilniaus Gedimino technikos universitetasen_US
dc.contributor.institutionVilnius Gediminas Technical Universityen_US
dc.contributor.facultyAplinkos inžinerijos fakultetas / Faculty of Environmental Engineeringen_US
dc.contributor.facultyFundamentinių mokslų fakultetas / Faculty of Fundamental Sciencesen_US
dc.contributor.departmentAplinkos apsaugos ir vandens inžinerijos katedra / Department of Environmental Protection and Water Engineeringen_US
dc.contributor.departmentChemijos ir bioinžinerijos katedra / Department of Chemistry and Bioengineeringen_US
dcterms.sourcetitle8th International Conference “Environmental Engineering” (ICEE-2011)en_US
dc.identifier.eisbn9789955288275en_US
dc.identifier.eissn2029-7092en_US
dc.publisher.nameVilnius Gediminas Technical Universityen_US
dc.publisher.nameVilniaus Gedimino technikos universitetasen_US
dc.publisher.countryLithuaniaen_US
dc.publisher.countryLietuvaen_US
dc.publisher.cityVilniusen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record