• Lietuvių
    • English
  • English 
    • Lietuvių
    • English
  • Login
View Item 
  •   DSpace Home
  • Universiteto produkcija / University's production
  • Universiteto leidyba / University's Publishing
  • Konferencijų medžiaga / Conference Materials
  • Jaunųjų mokslininkų konferencijos (JMK) / Conferences for Junior Researchers
  • Darni aplinka / Sustainable Environment
  • 23-oji konferencija „Aplinkos apsaugos inžinerija“ (2020) / 23rd Conference "Environmental protection engineering" (2020)
  • View Item
  •   DSpace Home
  • Universiteto produkcija / University's production
  • Universiteto leidyba / University's Publishing
  • Konferencijų medžiaga / Conference Materials
  • Jaunųjų mokslininkų konferencijos (JMK) / Conferences for Junior Researchers
  • Darni aplinka / Sustainable Environment
  • 23-oji konferencija „Aplinkos apsaugos inžinerija“ (2020) / 23rd Conference "Environmental protection engineering" (2020)
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Biologiniu būdu valytų nuotekų dezinfekavimo tyrimas

Thumbnail
View/Open
aainz.2020.015.pdf (844.4Kb)
Date
2020
Author
August, Paul
Dauknys, Regimantas
Metadata
Show full item record
Abstract
Šiame straipsnyje vertinamas mažų nuotekų kiekių dezinfekavimas taikant du skirtingo poveikio ultravioletine spinduliuote būdus: kai UV lempa kontaktuoja su nuotekomis ir kai ji nekontaktuoja. Nustatyta, kad abu būdai yra veiksmingi, tačiau tyrimų rezultatai rodo, jog po penkių savaičių eksploatacijos kontaktinio dezinfekavimo būdo atveju išvalymo rezultatai mažėja: įranga apsineša nuosėdomis ir rezultatai prastėja. Bekontakčio dezinfekavimo įrangos rezultatai stabilūs. E. coli bakterijų skaičius po dezinfekavimo nuolat didėjo – nuo 20 vnt./100 ml iki 95 vnt./100 ml, o bekontakčio dezinfekavimo atveju jis išliko pastovus ir svyravo nuo 10 vnt./100 ml iki 23 vnt./100 ml.
 
In this article we assess small wastewater treatment plants, effluent disinfection using two different methods using ultraviolet light. One when the lamp is submersed in the effluent, another when it has to direct contact with effluent. The results are: both methods are working properly, but the results show that after five weeks of exploitation, submerged disinfection had decreasing results. Results went from 20 units of bacteria per 100 milliliters of wastewater to 95 units per 100 milliliters of wastewater. Contactless method achieved similar results throughout the testing, ranging from 10 units per 100 ml. To 23 units per 100 ml. The results of treatment with submerged unit are decreasing because of debris on the unit. Results of contactless unit are stable throughout.
 
Issue date (year)
2020
Author
August, Paul
URI
https://etalpykla.vilniustech.lt/handle/123456789/155564
Collections
  • 23-oji konferencija „Aplinkos apsaugos inžinerija“ (2020) / 23rd Conference "Environmental protection engineering" (2020) [16]

 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjects / KeywordsInstitutionFacultyDepartment / InstituteTypeSourcePublisherType (PDB/ETD)Research fieldStudy directionVILNIUS TECH research priorities and topicsLithuanian intelligent specializationThis CollectionBy Issue DateAuthorsTitlesSubjects / KeywordsInstitutionFacultyDepartment / InstituteTypeSourcePublisherType (PDB/ETD)Research fieldStudy directionVILNIUS TECH research priorities and topicsLithuanian intelligent specialization

My Account

LoginRegister