• Lietuvių
    • English
  • English 
    • Lietuvių
    • English
  • Login
View Item 
  •   DSpace Home
  • Universiteto produkcija / University's production
  • Universiteto leidyba / University's Publishing
  • Konferencijų medžiaga / Conference Materials
  • Tarptautinės konferencijos / International Conferences
  • International Conference "Acoustic Climate Inside and Outside Buildings"
  • International Conference "Acoustic Climate Inside and Outside Buildings" (2014)
  • View Item
  •   DSpace Home
  • Universiteto produkcija / University's production
  • Universiteto leidyba / University's Publishing
  • Konferencijų medžiaga / Conference Materials
  • Tarptautinės konferencijos / International Conferences
  • International Conference "Acoustic Climate Inside and Outside Buildings"
  • International Conference "Acoustic Climate Inside and Outside Buildings" (2014)
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

An acoustic classification scheme for housing – possibilities of adopting COST TU0901 conclusions in Hungary

Thumbnail
View/Open
aciob.2014.02.pdf (57.15Kb)
Date
2014
Author
Nagy, Attila B.
Metadata
Show full item record
Abstract
The European Cost Action TU0901 “Integrating and Harmonizing Sound Insulation Aspects in Sustainable Urban Housing Constructions” was finished in 2013 [1]. Experts from 29 European and 3 overseers countries participated in the four year long cooperation in which the main objectives were to propose harmonized descriptors for airborne and impact sound insulation (1), and to propose a European acoustic classification scheme for dwellings (2).In most countries in Europe, building regulations specify minimum requirements about acoustical conditions for new dwellings: airborne and impact sound insulation, protection against outdoor sound [2] and sound due to service equipment. However, complying with regulatory requirements does not guarantee satisfactory conditions for the occupants –a classification scheme is needed where classes reflect levels of acoustical comfort. The classification scheme specifies criteria for six classes, from A – the highest – to F – the lowest – class. The complex criteria for each class specify minimum values for airborne sound insulation, maximum values for impact sound pressure level and sound pressure levels in the dwellings from service equipment, and maximum indoor sound levels or minimum values for insulation from outdoor noise from traffic, industry or other sources, in order to assure maximum indoor levels of such sources. Furthermore, maximum values for reverberation time classes for stairwells and common access areas are also included as optional parameters. A classification can be made for a dwelling or for a residential building, or even for an individual room. In this paper first the proposed harmonized sound insulation descriptors are introduced. After that the proposed harmonized classification scheme is presented and compared to the present Hungarian regulations. The applicability of the new system and the translation possibilities between the Hungarian and the new sound insulation descriptors are shown. Finally the guidelines for verifying compliance with an acoustic class are detailed.
Issue date (year)
2014
Author
Nagy, Attila B.
URI
https://etalpykla.vilniustech.lt/handle/123456789/156006
Collections
  • International Conference "Acoustic Climate Inside and Outside Buildings" (2014) [26]

 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjects / KeywordsInstitutionFacultyDepartment / InstituteTypeSourcePublisherType (PDB/ETD)Research fieldStudy directionVILNIUS TECH research priorities and topicsLithuanian intelligent specializationThis CollectionBy Issue DateAuthorsTitlesSubjects / KeywordsInstitutionFacultyDepartment / InstituteTypeSourcePublisherType (PDB/ETD)Research fieldStudy directionVILNIUS TECH research priorities and topicsLithuanian intelligent specialization

My Account

LoginRegister